IN sensor

 Main Features 

  • It measures nozzle pressures up to 4000 bar and melting temperatures of 400°C.
  •  Multi-shot measurements are possible at various pressure levels and temperatures below 230°C.
  •  It can be easily installed with magnets, without the need for screws.
  •  Combine the IN sensor with the nozzle touch force sensor.
  •  Ideal for services and development.
    (Measurements cannot be taken while the device is in operation.)



 Multishot 

To measure various pressures (up to 4000 bar), the IN tip can be heated with a heating band (maximum temperature 230°C).
In this way, the plastic injected into the dead volume remains in liquid form.
You can choose from steps of 500, 1000, 1500, and 2000 bar.



 single shot 

Even when the resin temperature exceeds 230°C (up to 400°C), pressure can be measured in a single shot.
The solidified plastic remaining inside the sensor must be removed after each shot.
 Magnetic attachment 

Thanks to the magnetic base, installation is very quick and easy.
This allows a nozzle check to be attached to the mold.
Technical data
Strain gauge type
Foil
Measurement range
4000bar
maximum contact force
300kN (for tie bars up to 60mm in diameter)
sensitivity
1.5 mV/V (nominal)
Accuracy error
< ± 0.5% FS
Linearity error
< 0.2% FS
Reproducibility error
< 0.2% FS
Operating temperature range
10°...+230°C (Up to 400°C in single-shot applications)
Storage Temperature Range
-20°C to +70°C
Protection class
IP50K
Case material
Stainless steel (high grade)